Filter Results By:

Products

Applications

Manufacturers

Showing results: 286 - 300 of 393 items found.

  • CT & PT Test Kit

    PCT200i - Scope T&M Pvt, Ltd.

    PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.

  • TOROIDAL COIL TURNS TESTER

    TURNS-TTPT - Vasavi Electronics

    Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns

  • Audio Impedance Testers

    1106 IM - Standard Electric Works Co., Ltd

    ● Large LCD : 68 × 34mm (2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.

  • Audio Impedance Testers

    1107 IM - Standard Electric Works Co., Ltd

    ● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.

  • High Voltage Test Set

    Hi-Pot Series - Scope T&M Pvt, Ltd.

    SCOPE introduces a high voltage test set, these high voltage testing sets comes with Power frequency AC high voltage /DC high Voltage test /AC-DC high Voltage test set for testing transformers, motors, insulators, cables etc. Further, these testing sets are capable of giving continuously variable HIGH VOLTAGE from zero to maximum rated output voltage. Wide range of up to 100 kV is available in user selectable combinations.

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • Transformer Winding Resistance Meters

    RMO TW Series - Amperis sl

    The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.

  • SF6 filled high precision Standard Capacitors

    YL Series - Shanghai Jiuzhi Electric Co., Ltd.

    The SF6 gas insulated standard capacitor is used together with a C and tan delta measuring bridge as the comparison standard leg of the bridge. It is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tand, Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.

  • Bobbin Winding Coil Tester

    SS108A series - Sanshine Electronis Co., Ltd.

    Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.

  • High Current Calibrator

    MC151 - Powertek LLC

    MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.

  • Precision LCR Meter (20Hz to 1MHz)

    ST2827 - Saluki Technology Inc.

    ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • Precision LCR Meter

    TH2827C - Changzhou Tonghui Electronic Co., Ltd.

    TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function  greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • Audio Impedance Testers

    2706 IM - Standard Electric Works Co., Ltd

    ● True measurement of speaker systems actual impedance at 1kHz.● Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operated.● Low battery indication.● Data hold function.● Timer function for continuous hands free operation.● The timer can last about 3-5 minutes when users press.● TEST ON/OFF button.

  • Test Sets For Diagnostic Testing

    NEO TELE-TRONIX PVT. LTD

    Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.

  • 904 Benchtop Six Phase 30A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.

Get Help